| Product summary | Detects overcurrent / locked rotor current and protects a motor from burnout |
|---|---|
| Product purpose | Prevent compressor motor burnout |
| Intended use | Compressor (for refrigerators, air conditioners, and other appliances) |
| Operating type | Bimetal type |
| Compatible standard | UL |
| Case material | Phenolic resin |
|---|---|
| Operating temperature range | Temperature near motor: 20°C to 100°C |
| Connection terminal type | Solder terminal |
| Product mounting method | Place the product into a Φ30 hole and bring it into intimate contact with the motor |
| Electrical Characteristics | AC 125/250V |
|---|---|
| Rated capacity | Up to 2.2 kW |
| Contact withstand current | 80/50A |
| Contact withstand count | 3,000 times or more |
| Withstand voltage | 1500 V for 1 minute |
| Insulation resistance | 100 MΩ or higher with a 500-VDC megohmmeter |